ECG accessories MCS

OVERVIEW

Electrodes are designed for use with modern “grabber” type mounts on patient cables of almost all types of electrocardiographs.

The use of a “button” for a grabber clamp increases the wear resistance of the cables themselves by eliminating mechanical damage as a result of twisting, bending and cyclic bending loads, which traditionally suffer from fasteners with banana plugs that are screwed to the electrode.

Advantages

  • Reliable and safe clips made of transparent polycarbonate. Withstand any impact and pressure.
  • Shallow polyurethane suction cups for chest electrodes with contact placed on the edge.
  • Thick* silver chloride sensor layer on top of the silver layer without the use of other metals for stable recording and low noise.
  • No thermal discomfort – feeling of warm electrodes when applied.
  • Color-coded with text explanations for the correct position of the clips.
  • The delicate but tight fit of the clips does not cause discomfort during a long procedure.
  • 2 mm push-button type contact for connecting safety connectors “Push-button” or “Clamp (Grabber)” parallel to the body. Provides minimal leverage to prevent the lead from being torn off by its own weight or pressure from the patient cable. The 4mm banana plug is connected via an adapter.
  • Adult and child sizes.

*100 microns instead of 5 microns for electrodes with a galvanic layer on top of the metal

SPECIFICATION

ECG chest electrodes MCS
  Adult Children
Diameter of electrode conductive surface < 24 mm < 14 mm
Material of conductive surface Ag/AgCl Ag/AgCl
Connector type snap snap
Dielectric strength of electrodes insulation > 30 V > 30 V
Resistance of electrodes insulation > 109 Ohm > 109 Ohm
Offset voltage (polarization) 100 mV (max) 100 mV (max)
Offset instability < 250 µV < 250 µV
Noise < 30 µV < 30 µV
The impedance of the electrode at 0.05 and 75 Hz ≤ 5 kΩ ≤ 5 kΩ
Time electrode readiness ≤ 10 minutes ≤ 10 minutes
Electrode continuous contact time at least 30 minutes at least 30 minutes
Vacuum pressure generated in the internal cavity of the suction electrode from 25 to 50 kPa from 15 to 30 kPa
Vacuum pressure reduction in 10 minutes < 15 % < 15 %
Force required to compress the suction electrode bulb < 25 N < 25 N
Useful life not less 1,5 years not less 1,5 years
Time to restore product serviceability under operational transportation conditions < 1 minute < 1 minute
Reusability reusable reusable
Net weight < 100 g < 50 g
ECG clips electrodes MCS
  Adult Children
Dimentions of electrode conductive surface 30 x 60 mm 14 x 30 mm
Electrode color coding (to identify patient cables) red, yellow, green, black red, yellow, green, black
Material of conductive surface Ag/AgCl Ag/AgCl
Connector type snap snap
Dielectric strength of electrodes insulation > 30 V > 30 V
Resistance of electrodes insulation > 109 Ohm > 109 Ohm
Offset voltage (polarization) 100 mV (max) 100 mV (max)
Offset instability < 250 µV < 250 µV
Noise < 30 µV < 30 µV
The impedance of the electrode at 0.05 and 75 Hz ≤ 5 kΩ ≤ 5 kΩ
Time electrode readiness ≤ 10 minutes ≤ 10 minutes
Electrode continuous contact time at least 30 minutes at least 30 minutes
Mean useful life not less 1,5 years not less 1,5 years
Time to restore product serviceability under operational transportation conditions < 1 minute < 1 minute
Reusability reusable reusable
Net weight < 100 g < 50 g

ECG electrodes are registered as part of the computer electrocardiograph CARDi according to MKDN.941311.017 TU, in the following versions: CARDi 2 and CARDi 2N-DB.

PHOTO