OVERVIEW
NeoRec cap 16 – EEG cap with 17 pre-installed Ag/AgCl sintered electrodes and 16-channel EEG amplifier with built-in accelerometer.
DC mobile EEG amplifiers NeoRec are designed to record EEG and other bioelectrical signals during scientific or medical research. Wireless data transfer to a PC in real-time via Bluetooth.
NeoRec cap is intended for:
- education, research and development in EEG,
- brain-computer interface and bio-feedback,
- neuromarketing, neurogaming and brain fitness.
SOFTWARE
EEG amplifier NeoRec 16 supports software NeoRec.
NeoRec is a PC software designed for experiment plannig and for recording EEG and other biomedical signals during scientific or medical research, include Evoked Potentials preprocessing.
Record files can be saved in different formats (EDF+ 16 bit, BDF+ 24 bit, GDF 32 bit) or transmited online via stream LSL (Lab Streaming Layer) for analyze by third party software as MATLAB / EEGLAB, OpenViBE etc.
SDK for software development for PC and mobile applications is provided by the manufacturer upon request.
SPECIFICATION
EEG amplifier | NeoRec 16 |
---|---|
EEG channels monopolar according to GND | 16 |
Electrode impedance measurement range | from 1 to 140 kOhm |
Time of continuous work | ≥ 15 hours |
Offline data recording | no |
Wireless data interface | BLE 4.2 |
Connector for connecting a cap/charger; | ST60‑18P |
Enclosure dimensions | 68 х 38 х 16 mm |
Weight of the amplifier | 40 g |
Recomended software | NeoRec |
Input dinamic range | ±150 mV, ±300 mV |
Accuracy of signal reproduction | 1 % |
Frequency range at -3 dB | 0 to 430 Hz (at 1000 Hz sampling rate) |
Sampling rate | 125 Hz, 250 Hz, 500 Hz, 1000 Hz |
Data resolution | 24 bit |
Noise (in operating range from 0.5 to 70 Hz) | 2 μV p‑p |
Input impedance | more 1 GOhm |
Events from internal smart accelerometer | activity (4 steps of sensitivity); change orientation (turn by 60°); free fall. |
Events from button | press |
Check of battery status | yes, by charge/discharge counting |
Charging of internal battery | from +5V USB adapter, 500 mA |
Time to fully charge the built-in battery | ≤ 2.5 hours |
ACCESSORIES
Wide range of EEG accessories MCScap are designed for NeoRec amplifiers. Different models of electrode caps with preinstalled Ag/AgCl sintered electrodes are covered all needs: from standard gel solution up to dry solution.
Textile caps in 12 sizes for the heads from 24 cm up to 66 cm circumference. Elastic material provides the most comfortable fit of the electrodes and the right positions without additional adjustment.
The material does not allow the gel or paste to dry out under electrodes fast. Marked holes for electrodes. Big holes for the opportunity to push the hair and prepare the skin for examination.
Reusable passive electrodes MCScap are based on high-quality Ag/AgCl sintered sensors which guarantee a high quality signal, a long-term stable electrical contact, a low noise reference electrode, a minimum electrode polarization, an excellent low frequency response.